Rain Bird SST-900i Istruzioni per gli Interventi Pagina 5

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 18
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 4
5
Figure 4:
This diagram details the wiring for three controllers operating one pump starter and
utilizing one Common wire, for all valves on all three controllers.
POWER SOURCE FOR
PUMP MOTOR STARTER
HOLDING COIL (110V OR
24V) AS REQUIRED BY
HOLDING COIL
POWER SOURCE TO
PUMP MOTOR
STARTER
L1 L2 L3
PUMP
MOTOR
STARTER
HOLDING COIL ON
PUMP MOTOR
STARTER
PUMP
MOTOR
CONTROLLER
A
M.V.
COM
CONTROLLER
B
CONTROLLER
C
COM
M.V.
COM
M.V.
AUX.
RELAYS
“A”
“B”
“C”
FIELD COMMON FOR ALL VALVES
B A
9
8 7
6
5 4
3
2 1
B A
9
8 7
6
5 4
3
2 1
14
13
12 11 10
8 7 6
4 3
2
1
5
9
Vedere la pagina 4